PPH POZIOM s.c.
ul. Sowińskiego 5
44-100 GLIWICE
POLAND

Manufacturer of measuring devices

Rotametry pływakowe czujniki poziomu cieczy Mass Flow Controllers - Rrotameters, Float Level Sensors


PDF document for printing

Mass flow controllers RNP

A mass flow controller (MFC) is a rotametric flow sensor with continuous measurement of temperature of flowing liquid (water, aqueous solutions) and is intended for thermostating:
  • injection moulds
  • moulds for shaping rubber by blowing
  • extruder heads
  • vacuum pumps
  • transformer welders
  • calibration devices
  • and other similar applications.

Design:
The mass flow controller consists of repeatable segments, the number of which depends on the number of thermostated circuits in the thermostated object.

Number of segments 1 2 3 4 5 6 7 8 9 10 11 12
L [mm] 74 128 182 236 290 344 398 452 506 560 614 668

Technical data:
Segment flow rate:
1. 250 l/h
2. 450 l/h
3. 1000 l/h
max. temp.: 80 °C
max. ciśnienie: 0,4 MPa
 
Construction materials:
ABS housing - PC rotameter tube
float - wykonanie:
1. PVC
2. aluminium alloy
3. brass
 
Principle of operation:
By opening the control and shut-off valve 2, we direct the liquid to the thermostatic object with the use of stub tube 3, then to the lower body 1 with the use of stub tube 4, where its temperature is measured. The flow rate of the fluid is set by means of valve 2 so as to obtain the assumed temperature of the thermostated object.

The regulator segment is composed of:
1 - bottom body
2 - control and shut-off valve
3 - straight stub tube
4 - angled stub tube
5 - bimetal thermometer
6 - rotameter flow indicator
7 - mounting sleeve
8 - korpusu górnego
9 - shut-off valve
10 - spacer screw

Disassembly and assembly of the rotameter tube:
Cut off the flow in the regulator segment with valves 2 and 9. The order of disassembly of the rotameter tube is determined by the numbers with the arrows. Install in reverse order.

Identification method:

1 - RNP - Mass Flow Controller
2 - segment flow
     performance:
               1 - 250 l/h
               2 - 450 l/h
               3 - 1000 l/h
3 - number of segments in the set
          01 - 1 segment
                -  "  -  "  -
                -  "  -  "  -
          12 - 12 segments


Order example:
Mass flow controller, 1000 l / h for one segment, 6 segments in the set:
RNP - 3 - 06

Warning!
The manufacturer reserves the right to introduce changes as part of product modernization.