PCP PC1 - technical data: | |
signal range: | 1000 mm |
pipe diameter: | Ø 12 mm |
float diameter: | Ø 44 mm |
level difference: | min. 80 mm |
specific gravity of the liquid: | ≥ 0,75 |
temp.: | max. 80 °C |
voltage: | 12-24 V DC |
switching current: | 0,5 A |
direct current: | 1 A |
reed switch functions: | NO, NC |
PCP PC2 - technical data: | |
signal range: | 500 mm |
pipe diameter: | Ø 8 mm |
float diameter: | Ø 29 mm |
level difference: | min. 50 mm |
specific gravity of the liquid: | ≥ 0,75 |
temp.: | max. 80 °C |
voltage: | 12-24 V DC |
switching current: | 0,5 A |
direct current: | 1 A |
reed switch functions: | NO, NC |
PCP PC1 G11/2'


material:
sensor – MO58, 1.4310
float – PP
protection level – IP 67
reed switch functions – NO, NC
number of signalling points – 1-3
PCP PC1 G11/2' A


material:
sensor – MO58, 1.4310
float – PP
protection level – IP 53
reed switch functions – NO, NC
number of signalling points – 1-3
PCP PC1 G 3/8' A


material:
sensor – MO58, 1.4310
float – PP
protection level – IP 68
reed switch functions – NO, NC
number of signalling points – 1-3
PCP PC1 G 3/8' B


material:
sensor – MO58, 1.4310
float – PP
protection level – IP 68
reed switch functions – NO, NC
number of signalling points – 1-3
PCP PC1 DN10


material:
sensor – ABS, MO58, 1.4310
float – PP
protection level – IP 65
reed switch functions – NO, NC
number of signalling points – 1 lub 2
PCP PC1 – PP – SK; PCP PC1 – PVC – SK


material:
| temp.: max. 80 °C
|
PCP PC2 G1'


material:
sensor – MO58, 1.4310
float – PP
protection level – IP 67
reed switch functions – NO, NC
number of signalling points – 1 lub 2
PCP PC2 G1' A


material:
sensor – MO58, 1.4310
float – PP
protection level – IP 53
reed switch functions – NO, NC
number of signalling points – 1 lub 2
PCP PC2 G 1/4' A


material:
sensor – MO58, 1.4310
float – PP
protection level – IP 68
reed switch functions – NO, NC
number of signalling points – 1 lub 2
PCP PC2 G11/4' B


material:
sensor – MO58, 1.4310
float – PP
protection level – IP 68
reed switch functions – NO, NC
number of signalling points – 1 lub 2
PCP PC2 DN10


material:
sensor – ABS, MO58, 1.4310
float – PP
protection level – IP 65
reed switch functions – NO, NC
number of signalling points – 1 lub 2
PCP PC2 –G1' – PP


material:
| temp.: max. 80 °C
|
PCP PC2 – PP


material:
| temp.: max. 80 °C
|